1.0 SCOPE
This document establishes the specifications for an outdoor, all dielectric, singlemode, dry block fiber optic cable in a loose buffer tube design.
2.0 APPLICABLE DOCUMENTS
Reference Documents: TIA/EIA FOTP Standards 455
Color Coding of Fiber Optic Cables TIA/EIA-598
RUS 1755.900
GR-20-CORE
3.0 REQUIREMENTS
This document contains test values for all-important mechanical, optical, and environmental parameters and as such, is the basis for all-incoming inspection and acceptance.
4.0 CABLE CROSS SECTION
|
Cross Section |
Components |
|
|
Central Member Water Swellable yarns Gel Filled Buffer Tube Filler Rod Binder Threads Water Blocking Core Tape Strength Elements Ripcord Outer Jacket
|
5.0 OVERALL CABLE CONSTRUCTION
5.1 Buffer tube
High Modulus Polymeric material.
Dimension: 2.8 mm., nominal.
Tube and fiber color code per EIA/TIA-598 or as specified by customer.
Filling compound: A non-toxic and dermatological safe antioxidant hydrocarbon based gel.
5.2 Dielectric Central strength member.
Epoxy glass rod with an up-coat of polymer (if necessary per construction).
Water swellable yarns are to be pulled in with the CSM.
5.3 Cable Core:
The cable elements are stranded around the CSM, using reverse oscillation.
Moisture Resistance: A water blocking tape is applied over the cable core to prevent water ingress and migration with a nominal of 25% overlap.
Non-wicking binder yarns are applied over the core tape.
5.4 Cable strength
Circumferential strength members are placed over the cable core and under the outer sheath.
5.5 Outer Sheath
UV Resistant Black Polyethylene. (or color per customer request)
A ripcord is applied under the outer sheath.
5.6 Cable Markings
Indent printed- REMFO 22 SERIES, FIBER OPTIC CABLE, # of fibers-SM, REMEE PRODUCTS CORP., TELEPHONE HANDSET SYMBOL, MM/YY (Month & Year of manufacture), Sequentially meter marked. Special print as required by customer.
5.7 Nominal Cable Dimensions & Weights
|
Remee Products Part Number |
No. of Fibers per Tube |
Cable OD (mm) |
Cable OD (in.) |
Weight KG/KM |
Weight LB/1000ft |
|
22-006-74M-EBSFWN |
6 |
11.3 |
.443 |
90 |
61 |
|
22-008-74M-EBSHWN |
8 |
11.3 |
.443 |
90 |
61 |
|
22-012-74M-EBSFWN |
6 |
11.3 |
.443 |
91 |
61 |
|
22-012-74M-EBSLWN |
12 |
11.3 |
.443 |
91 |
61 |
|
22-018-74M-EBSFWN |
6 |
11.3 |
.443 |
91 |
62 |
|
22-024-74M-EBSFWN |
6 |
11.3 |
.443 |
92 |
62 |
|
22-024-74M-EBSLWN |
12 |
11.3 |
.443 |
93 |
61 |
|
22-030-74M-EBSFWN |
6 |
11.3 |
.443 |
94 |
63 |
|
22-036-74M-EBSFWN |
6 |
12.0 |
.473 |
110 |
74 |
|
22-036-74M-EBSLWN |
12 |
11.3 |
.443 |
90 |
61 |
|
22-048-74M-EBSLWN |
12 |
11.3 |
.443 |
90 |
61 |
|
22-060-74M-EBSLWN |
12 |
11.3 |
.443 |
90 |
61 |
|
22-072-74M-EBSLWN |
12 |
12.0 |
.473 |
110 |
74 |
|
22-084-74M-EBSLWN |
12 |
13.0 |
.513 |
127 |
85 |
|
22-096-74M-EBSLWN |
12 |
13.9 |
.548 |
140 |
94 |
|
22-108-74M-EBSLWN |
12 |
15.1 |
.593 |
168 |
113 |
|
22-120-74M-EBSLWN |
12 |
16.0 |
.628 |
188 |
127 |
|
22-144-74M-EBSLWN |
12 |
17.7 |
.698 |
231 |
155 |
|
22-216-74M-EBSLWN |
12 |
18.6 |
.734 |
235 |
158 |
|
22-288-74M-EBSLWN |
12 |
21.4 |
.844 |
317 |
213 |
6.0 FIBER CHARACTERISTICS
|
Fiber Type |
Singlemode* |
|
Attenuation @ 1310/1550nm |
£.35/.25 dB/km |
|
Core Diameter, nominal |
8.3 µm |
|
Cladding Diameter |
125.0 ± 1.0 µm |
|
Primary Coating Diameter |
245 ± 10 µm |
|
Dispersion Slope |
£0.092 ps/nm2-km |
|
Fiber Cutoff Wavelength |
1150-1350nm |
|
Cabled Cutoff Wavelength |
<1260nm |
|
Mode Field Diameter @ 1310nm |
9.2 ± 0.4µm |
|
Mode Field Diameter @ 1550nm |
10.5 ± 1.0µm |
|
Cladding Non-circularity |
<1% |
|
Core/Clad Offset |
.80 µm |
|
Zero Dispersion Wavelength |
1300-1322nm |
|
Numerical Aperture |
0.13 |
|
Group Refractive Index @ 1310/1550nm |
1.467/1.4675 |
|
Proof Test |
100 kpsi |
*ITU G.652b
7.0 MECHANICAL & ENVIRONMENTAL PERFORMANCE
Maximum Tensile Load for: Impact Resistance: 25 Impacts (min.)
Installation: 2700N / 607lbf Flexing, ±90°: 25 Cycles (min.)
Long Term: 890N / 200lbf Temperature Rating:
Minimum bending radius: Operation, -40°C to +70°C
Loaded: 20 x diameter Installation, -40°C to +55°C
Unloaded: 10 x diameter Storage, -50°C to +70°C
Crush Resistance: 220N/cm Twist Test: 25 Cycles (min.)
8.0 PREPARATION FOR DELIVERY
The cable shall be packaged to preclude the inducement of damage due to handling and transportation, and shall be in accordance with the best commercial practices available.