1.0  SCOPE

This document establishes the specifications for an outdoor, all dielectric, singlemode, dry block fiber optic cable in a loose buffer tube design. 

 

2.0  APPLICABLE DOCUMENTS

      Reference Documents:         TIA/EIA FOTP Standards 455

                                                Color Coding of Fiber Optic Cables TIA/EIA-598

                                                RUS 1755.900

                                                GR-20-CORE

 

3.0  REQUIREMENTS

This document contains test values for all-important mechanical, optical, and environmental parameters and as such, is the basis for all-incoming inspection and acceptance.

 

4.0   CABLE CROSS SECTION

Cross Section

Components

 

Central Member

Water Swellable yarns

Gel Filled Buffer Tube

Filler Rod

Binder Threads

Water Blocking Core Tape

Strength Elements

Ripcord

Outer Jacket

 

 

5.0   OVERALL CABLE CONSTRUCTION

5.1  Buffer tube

   High Modulus Polymeric material.

   Dimension: 2.8 mm., nominal.

Tube and fiber color code per EIA/TIA-598 or as specified by customer.

   Filling compound: A non-toxic and dermatological safe antioxidant hydrocarbon based gel.

5.2   Dielectric Central strength member.

Epoxy glass rod with an up-coat of polymer (if necessary per construction).

Water swellable yarns are to be pulled in with the CSM.

      5.3  Cable Core:

   The cable elements are stranded around the CSM, using reverse oscillation.

Moisture Resistance: A water blocking tape is applied over the cable core to prevent water ingress and migration with a nominal of 25% overlap.

   Non-wicking binder yarns are applied over the core tape.

      5.4  Cable strength

Circumferential strength members are placed over the cable core and under the outer sheath. 

      5.5  Outer Sheath

   UV Resistant Black Polyethylene. (or color per customer request)

   A ripcord is applied under the outer sheath.

      5.6  Cable Markings

Indent printed- REMFO 22 SERIES, FIBER OPTIC CABLE, # of fibers-SM, REMEE PRODUCTS CORP., TELEPHONE HANDSET SYMBOL, MM/YY (Month & Year of manufacture), Sequentially meter marked.  Special print as required by customer.

 

 

 

 

5.7   Nominal Cable Dimensions & Weights

 

Remee Products

Part Number

No. of Fibers per Tube

 

Cable

OD (mm)

 

Cable

OD (in.)

 

Weight  KG/KM

 

Weight  LB/1000ft

22-006-74M-EBSFWN

6

11.3

.443

90

61

22-008-74M-EBSHWN

8

11.3

.443

90

61

22-012-74M-EBSFWN

6

11.3

.443

91

61

22-012-74M-EBSLWN

12

11.3

.443

91

61

22-018-74M-EBSFWN

6

11.3

.443

91

62

22-024-74M-EBSFWN

6

11.3

.443

92

62

22-024-74M-EBSLWN

12

11.3

.443

93

61

22-030-74M-EBSFWN

6

11.3

.443

94

63

22-036-74M-EBSFWN

6

12.0

.473

110

74

22-036-74M-EBSLWN

12

11.3

.443

90

61

22-048-74M-EBSLWN

12

11.3

.443

90

61

22-060-74M-EBSLWN

12

11.3

.443

90

61

22-072-74M-EBSLWN

12

12.0

.473

110

74

22-084-74M-EBSLWN

12

13.0

.513

127

85

22-096-74M-EBSLWN

12

13.9

.548

140

94

22-108-74M-EBSLWN

12

15.1

.593

168

113

22-120-74M-EBSLWN

12

16.0

.628

188

127

22-144-74M-EBSLWN

12

17.7

.698

231

155

22-216-74M-EBSLWN

12

18.6

.734

235

158

22-288-74M-EBSLWN

12

21.4

.844

317

213

 

6.0   FIBER CHARACTERISTICS

Fiber Type

Singlemode*

Attenuation @ 1310/1550nm

£.35/.25 dB/km

Core Diameter, nominal

8.3 µm

Cladding Diameter

125.0 ± 1.0 µm

Primary Coating Diameter

245 ± 10 µm

Dispersion Slope

£0.092 ps/nm2-km

Fiber Cutoff Wavelength

1150-1350nm

Cabled Cutoff Wavelength

<1260nm

Mode Field Diameter @ 1310nm

9.2 ± 0.4µm

Mode Field Diameter @ 1550nm

10.5 ± 1.0µm

Cladding Non-circularity

<1%

Core/Clad Offset

.80 µm

Zero Dispersion Wavelength

1300-1322nm

Numerical Aperture

0.13

Group Refractive Index @ 1310/1550nm

1.467/1.4675

Proof Test

100 kpsi

            *ITU G.652b

 

 

 

 

 

 

 

7.0  MECHANICAL & ENVIRONMENTAL PERFORMANCE

Maximum Tensile Load for:                                                   Impact Resistance: 25 Impacts (min.)

                  Installation:  2700N / 607lbf                                 Flexing, ±90°: 25 Cycles (min.)

                  Long Term:  890N / 200lbf                                   Temperature Rating:                                          

Minimum bending radius:                                                                  Operation,         -40°C to +70°C

                  Loaded: 20 x diameter                                                    Installation,        -40°C to +55°C

                  Unloaded: 10 x diameter                                     Storage,            -50°C to +70°C

Crush Resistance: 220N/cm                                                 Twist Test: 25 Cycles (min.)

 

8.0   PREPARATION FOR DELIVERY

The cable shall be packaged to preclude the inducement of damage due to handling and transportation, and shall be in accordance with the best commercial practices available.