SURPLUS INVENTORY WANTED, WE PAY CASH.
CLICK ON THUMBS TO ENLARGE
NEW PURCELL CABINETS LOADED AND NICE 17 AVAILABLE. SEE SPEC SHEET. LOCATED IN co
11.5' X 28' 2001 FIBREBOND SHELTER , DRAWING number D-5400 1 AVAILABLE. dual 6ton bard hvac'S, dual gen plugs, 2 ea 200 amp panels with 42cts, racking, grounding, 120/240VOLT SERVICE ON 400 AMP BREAKER, 65k wt. NICE UNIT. LOCATED IN Washington state
10x12' 17 AVAILABLE. FIBERBOND, DUAL 2TON, 200 AMP PANEL, 2000 manufacture, Located in IL
12X32' DOUBLE FIBREBOND SHELTER 1 AVAILABLE. THREE hvac'S, halon fire system, racking, grounding, 120/240VOLT SERVICE ON 400 AMP BREAKER, ATS, NICE UNIT LIKE NEW INTERIOR AND OUTSIDE JUST NEEDS PRESSURE WASH. LOCATED IN MCALLEN, TX
They were made for Adelphia and they spared zero expense in putting them together and were originally $100k buildings with everything. I also got a quote from Fibrebond on what it would take to mobilize and break it down for a crane to pick-up. Here are the figures Here are the numbers: Mobilize Technicians to McAllen, TX $ 850, Break-down /Close-up Bldg. $ 6,600
10'X20' PRECISION QUINCY 3 AVAILABLE. LIGHT WEIGHT SHELTERS, DUAL HAVC, 200 AMP PANEL, CABLE RACKING, ECT... STANDARD STUFF. NICE UNITS
Welded steel construction strong and impervious to insects and mold. Rock-solid aggregate exterior appealing precast concrete appearance with less weight. Galvannealed steel roof and truss system maintenance free and impact resistant. Fully insulated and finished interiors durable, low maintenance and light reflective, Light weight reduced transportation and site construction costs, Gable roof design attractive low profile with passive ventilation, Polyurethane paint durable and corrosion resistant. FLOOR LOAD (PSF) 225MIN, SNOW LOAD (PSF) 80MIN, WIND LOAD (MPH_ 130OR 150, INTERIOR HEIGHT 8' OR 9'
12' X 24' communications building 1 AVAILABLE. Advance Industries Aluminum approx. with internal ground system, HVAC Approx. 136 in inside width x 279 in inside length x 104 in inside height Dayton temp alarm, Crispaire lead lag controller, Honeywell thermostat. 100 Amp 24 position load center, Portable generator safety switch and 100 A plug Two, two ton Marvair air conditioners. Electric heat Two, 4 x 2 cable entry ports. This building is in great shape! units located in Champaign, il
Generator Details: 1 AVAILABLE Onan model 30.0 SK-3R/21404A ,Serial I790447678, time rating standby, 1 phase 30kw 37.5 kva, Used Onan backup generator system (currently 120/240 single phase, propane) mounted in an Aluminum Mobile International portable building. This system was previously used by MCI Telecom on their microwave communication route. 12v battery, Gauges on control panel include: battery, engine oil press, water temp, AC volts, AC amps (2), hertz and system status panel. Safety shutdown for hi temp, over crank, low oil pressure, overspeed. 362.2 hours on current hour meter. Chrysler 6 cylinder 225 cui, Model H225,Serial E 524859, p/n 4142270, Building Details:
Microvan Mobile International Aluminum building Approx. dimensions External dimensions - 95" wide by 109" long by 112" high, This does not include the intake and exhaust vents which would need to be removed for transit and bolted back on at final destination. Solid 36" wide by 81" high man door. Aluminum exterior construction on 4" by 6" steel skids base. located in Champaign, ilInternal 88" wide by 102" long by 96" inside height. Two fluorescent light fixtures. Barber-Coleman actuators and louvers for intake. Onan automatic transfer switch (OT) w/ voltage sensor and time delay board. Square D portable generator input safety switch 200A 240AC cat#82254. Square D QOC16W load center
1/3 pos 50A, 5 pos 20A, 7 pos 20A, 9 pos 15A(engine block heater), 2/4 pos 20A heat, 6/8 pos 20 A heat, 10 pos 20 A. White-Rodger thermostat type 1A65. Square D main disconnect 100A J353642
10x16' 3 AVAILABLE. cellxion, end door units, with wave guide ports at air conditioner end. DUAL 2TON, 200 AMP PANEL, 2000 models, nice shelters. Located in al
12'X30' 1 AVAILABLE. FIBERBOND DUAL 2TON, 200 AMP PANEL, NEW FLOOR TO BE INSTALLED, 200 AMP AUTO-TRANSFER SWITCH, 30KW GENERAC GENERATOR W/670 HOURS Located in HOUSTON, TX
24' x 36' fibrebond premier concrete / two piece module shelter, 1 AVAILABLE, like new condition, 4" thick walls, and steel rebar reinforced concrete, bullet resistant, three exterior doors, 400amp panel, seismic zone 4 rated, three *4) ton bard hvac w/heat-strips and controls, economizer cycles, ac electrical, estimated wt per side 68,000lbs, fully stocked, ready to deploy. located in la
NEW purcell cabinets 17 AVAILABLE, Shelters are located in tx.




$15,500 priced
for quick sale.
12' X 30' ANDREW CONCRETE, has partition and venting for generator and separate door 1 AVAILABLE have drawings. Shipping Weight 63,000+lbs. LOCATED DENTON, TEXAS
10x12' 1 AVAILABLE. cellxion, DUAL 2TON, 200 AMP PANEL, 2000 manufacture, Located in ,al
NEW ERICSSON SHELTERS 19 AVAILABLE, Shelters are 15 ft x 5.5 ft x 8.5 ft high.
Each has battery/rectifier installed and HVAC, Re-designed Ericsson 24V DC power system the batteries are C & D Liberty 2000. rectifiers are Emerson/Ericsson). weight 15,000 (with the installed 1000 AH @+24vDC batteries installed.
Additionally, we have a quantity of 'spare' (uninstalled) batteries. (Note: The charger/rectifiers are 220 VAC @ 60 Hz input). The shelters are Aluminum, with the DUAL 2.5TON HVAC units made by Gichner Shelter Systems (PA). All-weld frame and insulated unibody design (15x1700w rectifiers) Slide lever locking handles on doors
Tested against relevant shelter Bell-Core standards Corrosion Resistant Designated space for EDGE Space and Support for High Capacity RBS Configurations.
Half hour battery back up at 70% (3X32), CCU by Chrisp Aire wind tolerant to 110 mph+ (split unit for redundancy), Complete unit approx. 13,000 lbs., Generator hook-up provided (M/F ends), All cable entries BOX TEC ports, GFI receptacles, New 24V DC lighting, 19" rack for customer support equipment, Optional 3 Phase power (to be designed), Optional dehumidifier, DC fans for ambient air flow, LOCATED IN VIRGINIA


SIDE DOOR UNITS
END DOOR UNITS
$18,500
12'x 26' precision quincy shelters, 18 AVAILABLE, currently on hold, very nice condition, look new, DUAL 4 or 6 ton briard HVAC, 200AMP or 400amp electrical, END DOORS OR SIDE DOORS, alarms and smoke detectors, 22lbs, LOCATED il
Welded steel construction strong and impervious to insects and mold. Rock-solid aggregate exterior appealing precast concrete appearance with less weight. Galvannealed steel roof and truss system maintenance free and impact resistant. Fully insulated and finished interiors durable, low maintenance and light reflective, Light weight reduced transportation and site construction costs, Gable roof design attractive low profile with passive ventilation, Polyurethane paint durable and corrosion resistant. FLOOR LOAD (PSF) 225MIN, SNOW LOAD (PSF) 80MIN, WIND LOAD (MPH_ 130OR 150, INTERIOR HEIGHT 8' OR 9'
NEW ERICSSON SHELTERS 9 AVAILABLE, Shelters
The shelters are Aluminum, with the DUAL 2TON HVAC units made by Gichner Shelter Systems (PA). All-weld frame and insulated unibody design (15x1700w rectifiers) Slide lever locking handles on doors
Tested against relevant shelter Bell-Core standards Corrosion Resistant Designated space for EDGE Space and Support for High Capacity RBS Configurations.
Half hour battery back up at 70% (3X32), CCU by Chrisp Aire wind tolerant to 110 mph+ (split unit for redundancy), Complete unit approx. 13,000 lbs., Generator hook-up provided (M/F ends), All cable entries BOX TEC ports, GFI receptacles, New 24V DC lighting, 19" rack for customer support equipment, Optional 3 Phase power (to be designed), Optional dehumidifier, DC fans for ambient air flow, LOCATED IN VIRGINIA
10x16' 17 AVAILABLE. cellxion, DUAL 2TON, 200 AMP PANEL, 2000 models, nice shelters. Located in mobile, al
10x12' 1 AVAILABLE. cellxion, DUAL 2TON, 200 AMP PANEL, 2000 manufacture, Located in mobile, al
LIGHTENING PROTECTION CABINETS, 4 AVAILABLE. PART NUMBER NTPA08LA, USED AND IN GOOD CONDITION, Located in ga
10X14' 2 AVAILABLE. These are former MCI buildings and they did not spare any expense in putting them together. Located in MI
They are also set-up as generator buildings so you can slide a generator into them with ease if needed (anywhere typically from 25kw to 45kw normally. 200 AMP PANEL, DISTRIBUTION PANEL 120/240 VOLT, SINGLE PHASE, DISCONNECT SWITCH, EXHAUST LOUVER AND MOTORIZED INTAKE LOUVER WITH SCREENS, REMOVABLE DOOR AND END WALL FOR INSERTION OR EXTRACTION OF GENERATOR, BASE BOARD HEATERS, 3/0 X7/0 ALUMINUM DOOR (3 5/8" THICK) STAINLESS HINGES AND 3PT DOOR LOCKING HARDWARE. WIND LOAD 100MPH, ROOF LOAD: 50LBS PSF, FLOOR LOADING 250LBS PSF. 3" O.D. TOW PIPE ON EACH END. SHELTER WEIGHT: 9400LBS. We can get a 2-ton HVAC unit put onto these shelters for you. They are in good condition and we can have them spit shined before they go out. NO CHARGE FOR LOADING.
10X10' 10 AVAILABLE. These are former MCI buildings and they did not spare any expense in putting them together. Located in MI
They are also set-up as generator buildings so you can slide a generator into them with ease if needed (anywhere typically from 25kw to 45kw normally. 200 AMP PANEL, DISTRIBUTION PANEL 120/240 VOLT, SINGLE PHASE, DISCONNECT SWITCH, EXHAUST LOUVER AND MOTORIZED INTAKE LOUVER WITH SCREENS, REMOVABLE DOOR AND END WALL FOR INSERTION OR EXTRACTION OF GENERATOR, BASE BOARD HEATERS, 3/0 X7/0 ALUMINUM DOOR (3 5/8" THICK) STAINLESS HINGES AND 3PT DOOR LOCKING HARDWARE. WIND LOAD 100MPH, ROOF LOAD: 50LBS PSF, FLOOR LOADING 250LBS PSF. 3" O.D. TOW PIPE ON EACH END. SHELTER WEIGHT: 7900LBS. We can get a 2-ton HVAC unit put onto these shelters for you. They are in good condition and we can have them spit shined before they go out. NO CHARGE FOR LOADING.
12X20' KONTEC concrete shelters, 2 AVAILABLE v120/240 volt service, 200 amp center, ladder racking, generator receptacle, marvair hvac, WT IS 41K LOCATED IL
10x12' 30 AVAILABLE fiberbond concrete shelters, 5-7 years of age.
v120/240 volt service, 200 amp center, ladder racking, generator receptacle, 2 ton marvair hvac, lead/lag hvac controller, high temp alarm, low temp alarm, fire extinguisher, quadareplex receptacles, commercial power fail, smoke detector, 200 amp generator receptacle, unican lockset, exterior light switch, magnetic door alarm, dual flood light w/motion, d.c. fail safe alarm exterior ground bar, alarm terminal block, 24 hour timer, humidistat for dehumidifier, vent fan wt is 25k LOCATED la
$12,500
PDF FILE
argus Tempest cabinet 1 AVAILABLE Model TE12, P/N 039-357-20 NEW SURPLUS location wa
10'x 20' precision quincy shelters, 6 AVAILABLE, very nice condition, DUAL HVAC, 200AMP Panel, wt is 9-12k, LOCATED il,
Welded steel construction strong and impervious to insects and mold. Rock-solid aggregate exterior appealing precast concrete appearance with less weight. Galvannealed steel roof and truss system maintenance free and impact resistant. Fully insulated and finished interiors durable, low maintenance and light reflective, Light weight reduced transportation and site construction costs, Gable roof design attractive low profile with passive ventilation, Polyurethane paint durable and corrosion resistant. FLOOR LOAD (PSF) 225MIN, SNOW LOAD (PSF) 80MIN, WIND LOAD (MPH_ 130OR 150, INTERIOR HEIGHT 8' OR 9'
6.5'x 8' switzer shelters, 1 AVAILABLE very nice condition, HVAC, 200AMP Panel, LOCATED in post falls, id
The Freedom Series is the perfect shelter for today's communications infrastructure. These maintenance-free fiberglass composite shelters are insulated, weather-tight, durable and secure. The high strength-to-weight ratio provides all the protection you need in a package that is easy to handle. This is especially beneficial for hard to reach locations such as roof-tops, mountain-tops, and international sites where the logistics of shipping and handling and site preparation might otherwise be cost prohibitive.
$15,500 priced
for quick sale.
12' X 28' ANDREW CONCRETE, has partition 1 AVAILABLE Shipping Weight 62,000+lbs. LOCATED DENTON, TEXAS
12' x 20' miller CONCRETE SHELTER 2 AVAILABLE, 200 AMP LOAD CENTER, single HVAC CONTROLLER, GROUNDING, WEIGHT IS APPROX. 40K, can stamp for any state, LOCATED IN oh


$17,000 drawings
12' x 20' andrew CONCRETE SHELTER 2 AVAILABLE, 200 AMP LOAD CENTER, dual 3ton HVAC CONTROLLER, GROUNDING, WEIGHT IS APPROX. 44K, can stamp for any state, LOCATED IN oh
26,500
12' X 20' factory new ROHN CONCRETE SHELTER with warranty, 1 AVAILABLE 200 AMP LOAD CENTER, RECEPTACLES, 2EA 3TON bard HVAC UNITS, HI/LOW TEMP ALARM SYSTEM, RACKING, GROUNDING, LOCATED IN ILLINOIS
10' X 10' FIBERCRETE CONCRETE SHELTER 1 AVAILABLE,
200 AMP LOAD CENTER, HVAC CONTROLLER, GROUNDING, CRANE AVAILABLE to load SOON WHEN TOWERS TAKEN DOWN, needs a little cleaning and paint, its concrete and built to last. WEIGHT IS APPROX. 12K, LOCATED IN GROVETON, TEXAS
12' X 26' FORT WORTH SHELTER 20 AVAILABLE, 200 AMP LOAD CENTER, HVAC CONTROLLER, 2EA 3TON HVAC UNITS, RACKING, GROUNDING, WEIGHT IS APPROX. 52K, CAN ENGINEER FOR ANY STATE, LOCATED IL.
10' X 20' FORT WORTH SHELTER 2 AVAILABLE, 200 AMP LOAD CENTER, HVAC CONTROLLER, 2EA 3TON HVAC UNITS, RACKING, GROUNDING, CRANE AVAILABLE CLOSE BY, WEIGHT IS APPROX. 48K, CAN ENGINEER FOR ANY STATE AT 2500.00, LOCATED IN IL.
TELCO SERVICE CABINETS 20 AVAILABLE LOCATED IN CHICAGO, IL
1400.00 NEW MARVAIR 3 TON HVAC FOR SHELTERS 40 AVAILABLE LOCATED IN CHICAGO, IL
1400.00 NEW BARD 3 TON HVAC FOR SHELTERS 36 AVAILABLE LOCATED IN CHICAGO, IL
750.00 NEW MARVAIR 2 TON HVAC FOR SHELTERS 35 AVAILABLE LOCATED IN CHICAGO, IL
12' X 28' ROHN CONCRETE USED SHELTER 1 AVAILABLE DOUBLE DOOR 3' X 7', 200 AMP LOAD CENTER, RECEPTACLES, 1EA HVAC CONTROLLER, 2EA 3TON HVAC UNITS RACKING, GROUNDING, LOCATED IN SIKESTON, NEW MADRID COUNTY, MO
11'.6" X '18 FIBERBOND CONCRETE, SHELTER 4 AVAILABLE 200 AMP LOAD CENTER, HVAC CONTROLLER, NEW HVAC UNIT, AS PICTURED, NO CHARGE FOR CRANE LOADING THE MONTH OF FEB. LOCATED IN BALTIMORE, MA.
10' X 32' FIBERBOND CONCRETE, 1995 USED SHELTER 1 AVAILABLE 200 AMP LOAD CENTER, CALIFORNIA APPROVED STAMP, WIND SPEED 110MPH, ROOF LOAD 60LBS SQ. FT. FLOOR LOAD 150LBS PER SQ. FOOT., SEISMIC ZONE 4, RECEPTACLES, 1EA HVAC CONTROLLER, 2EA 3TON HVAC UNITS RACKING, GROUNDING, LOCATED IN DELAND AIRPORT, i4 &95, DAYTONA BEACH, FL.
11.6' X 28' MILLER CONCRETE AS NEW, USED SHELTER 4 AVAILABLE 200 AMP LOAD CENTER, RECEPTACLES, 1EA HVAC CONTROLLER, 2EA 3TON HVAC UNITS RACKING, GROUNDING, LOCATED IN BALTIMORE, MD.
17,500
ACTUAL PHOTOS SOON
10' X 20' ROHN CONCRETE USED SHELTER 50 AVAILABLE 200 AMP LOAD CENTER, RECEPTACLES, 1EA HVAC CONTROLLER, 2EA 3TON HVAC UNITS, HI/LOW TEMP ALARM SYSTEM, RACKING, GROUNDING, LOCATED IN ILLINOIS
2' x 2' 16 AVAILABLE NEW OUTDOOR ALPHA BOXES WITH FIBERGLASS PAD STILL ON CRATE, LOCATED Nebraska
EMERSON MINI CABINETS, 2 AVAILABLE communications equipment.
The enclosure is a complete equipped enclosure includes cooling and supervision for outdoor use. All prepared for standard indoor racks applicable for GSM, 3G and beyond. The enclosure allows fast roll-out and quick on-site installation. Air to Air Heat Exchanger or Active Cooling & Air to Air, Air flow noise reducers, IP 55 class protection, DC Power fans, -48VDC or +24VDC. Small footprint 1300 x 1045 mm (W x D),Located in Bolder CO. 80301
http://products.emersonenergy.com/sales/products/displayproduct.asp?id=113&PGroup=All
10'X12' 6 AVAILABLE, NEW CONCRETE SHELTER, 2ea 4ton HVAC, 2ea Doors, Surge Protection, Ladder Rack, Motion Sensors, LOCATED IN BOSTON, MA
$26,000 NEW
CONCRETE ROHN SHELTER
12'X20' 1 AVAILABLE, NEW CONCRETE ROHN SHELTER, 2ea 3ton HVAC, 1ea Doors, Surge Protection, Ladder Rack, Motion Sensors, lights, tile floor, 200AMP, Generator Plug, Auto Transfer switching. LOCATED IN Chicago, IL

26,000
NEW CONCRETE ROHN SHELTER
12' X 30' 3 AVAILABLE, New Concrete Shelter (4 Door, 2 per end) 2ea Marvair 4-ton W/9kw heat strip, 3-phase, 125A distribution Panel, (1-phase optional), Fenced internally for collocation (removable), four ground bars, Entry ports on both sides, Alarm Panel, Shipping Weight 63,000lbs. 1 Located PA. CLICK FOR DRAWINGS
28,500 NEW
CONCRETE ROHN SHELTER
10'x24' 1 AVAILABLE, New Rohn Concrete Shelters, 2ea 4ton HVAC, 4ea Doors, 200amp/120volt Distribution Panel, Ladder Rack, Lighting, Generator plug, located in IL.
12'x20' 12 AVAILABLE, Rohn Fiberglass Shelters, 1 HVAC, 200amp/120volt Distribution Panel Disconnect, Lighting, Reinforced with Heavy -Duty metal Frame and 12 Cable Port Entrances, Lighting, located in OH, IN CLICK FOR DRAWINGS
11'x18' 2 AVAILABLE, NICE Fort Worth Shelters, 2ea 4ton HVAC, 150amp/120volt Distribution Panel, Ladder Rack, 2 cable Port Entrances, Lighting, located in OK, AL, IL. CLICK FOR DRAWINGS